Pulsafeeder Pulsar Series HypoPump Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Čerpadla Pulsafeeder Pulsar Series HypoPump. Pulsafeeder Pulsar Series HypoPump User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 15
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
USER NOTE: This serves as additional information for Pulsafeeder PULSAR® and PULSAR Shadow® metering pumps
equipped with the Automatic Valve Assembly for purging trapped gasses from the reagent head. You must also reference
the latest revision of the complete PULSAR® or PULSAR Shadow® pump IOM for critical safety and operational
information.
PULSAR
®
HYPOPUMP
®
SODIUM HYPOCHLORITE
METERING PUMP
Bulletin #: PS-IOM-HYP-0203-I
Installation, Operation &
Maintenance Instruction
Zobrazit stránku 0
1 2 3 4 5 6 ... 14 15

Shrnutí obsahu

Strany 1 - Maintenance Instruction

USER NOTE: This serves as additional information for Pulsafeeder PULSAR® and PULSAR Shadow® metering pumps

Strany 2 - Revision History:

6 7. Description and Operation 7.1 Principle of Operation Reciprocating metering pumps are used with a wide variety of chemicals, such as sodium hy

Strany 3 - Table of Contents

7 8. Maintenance NOTE: This section only refers to models purchased and installed prior to [date] and is for reference only. Replacement parts are n

Strany 4 - 1. Conventions

8 8.2 Flapper Valve Replacement 1. Remove automatic valve assembly completely from pump, as per the instructions in the previous section. 2. Remove

Strany 5 - 2. General Safety

9 9. Troubleshooting Guide Symptom Probable Cause Possible Solution Pump does not prime (product side) Purge relay not operational Verify power is

Strany 6 - 4. Storage

10 10. Wiring Diagrams Figure 7 It is recommended that the AVA be powered from a Ground Fault Circuit Interrupter (GFCI) protected electrical circui

Strany 7 - 5. Overall System Diagram

11 PULSAR® HYPOPUMP® SODIUM HYPOCHOLORITE METERING PUMP Bulletin #: PS-IOM-HYP-0203-I A unit of IDE

Strany 8 - 6. Installation

ii FACTORY SERVICE POLICY If you are experiencing a problem with your Pulsafeeder pump, first review the IOM, and consult the troubleshooting guide.

Strany 9 - 6.3 Electrical Wiring

iii Table of Contents 1. CONVENTIONS ...

Strany 10 - 7.2 General Description

iv 1. Conventions For the remainder of this bulletin, the following Conventions are in effect. A WARNING DEFINES A CONDITION THAT COULD CAUSE DAMA

Strany 11 - 8. Maintenance

1 2. General Safety The Automatic Valve Assembly (AVA) was designed as a gas handling/priming aid for operation solely with Pulsafeeder PULSAR® and

Strany 12

2 3. Equipment Inspection When you receive your order, check all equipment for:  Completeness against the shipping document / purchase order  Evi

Strany 13 - 9. Troubleshooting Guide

3 5. Overall System Diagram Figure 1PULSAR® HypoPump® System Diagram

Strany 14 - 10. Wiring Diagrams

4 6. Installation 6.1 Location Review the Safety section prior to installing the pump with AVA. It contains information required to properly insta

Strany 15 - HYPOPUMP

5 AVOID LOCATIONS WHERE THE AVA WOULD BE SUBJECTED TO EXTREME COLD OR HEAT OR DIRECT SUNLIGHT. FAILURE TO OBSERVE THIS WARNING COULD DAMAGE THE AVA

Komentáře k této Příručce

Žádné komentáře